Which Indicator Is Used In Mohr’s Method?
Answer
573.6k+ views
Hint: The silver(I) ion is used in argentometry, which is a kind of titration in analytical chemistry. It's often used to figure out how much chloride is in a sample. The sample solution is titrated against a known concentration of silver nitrate solution. Chloride ions react with silver(I) ions to form silver chloride, which is insoluble:
\[A{g^ + }\;\left( {aq} \right){\text{ }} + {\text{ }}C{l^ - }\;\left( {aq} \right){\text{ }} \to {\text{ }}AgCl{\text{ }}\left( s \right){\text{ }}(K\; = {\text{ }}5.88{\text{ }} \times {\text{ }}{10^9})\]
Complete answer:
Potassium chromate is used as an indicator in the Mohr technique, which produces red silver chromate when all chloride ions have interacted.
\[2A{g^ + }\;\left( {aq} \right){\text{ }} + {\text{ }}Cr{O^{2 - }}_4\;\left( {aq} \right){\text{ }} \to {\text{ }}A{g_2}Cr{O_4}\;\left( s \right){\text{ }}({K_{sp}}\; = {\text{ }}1.1{\text{ }} \times {\text{ }}{10^{ - 12}})\]
Because silver hydroxide forms at high pH whereas chromate creates H2CrO4 at low pH, the solution must be near neutral to reduce the concentration of chromate ions and delay the development of the precipitate. Carbonates and phosphates precipitate with silver and must be avoided in order to avoid erroneous findings.
By burning a sample with calcium and subsequently ferric acetate, the Mohr technique may be used to estimate the total chlorine concentration of a sample. Free chlorine is "fixed" by calcium acetate, which precipitates carbonates and neutralises the resulting solution. Phosphates are removed by ferric acetate. The residue is dissolved and titrated to remove any chlorides.
Note:
Typically, dichlorofluorescein is employed as an indicator in the Fajans technique; the end-point is identified by the green suspension becoming pink. Chloride ions are still in excess prior to the titration's completion. They adsorb on the AgCl surface, giving the particles a negative charge. Excess silver(I) ions attach on the AgCl surface after the equivalence point, imparting a positive charge. Anionic dyes like dichlorofluorescein are attracted to the particles and change colour as they adsorb, indicating the end-point. Eosin gives a sharper end-point than dichlorofluorescein when titrating against bromide, iodide, and thiocyanate anions.
\[A{g^ + }\;\left( {aq} \right){\text{ }} + {\text{ }}C{l^ - }\;\left( {aq} \right){\text{ }} \to {\text{ }}AgCl{\text{ }}\left( s \right){\text{ }}(K\; = {\text{ }}5.88{\text{ }} \times {\text{ }}{10^9})\]
Complete answer:
Potassium chromate is used as an indicator in the Mohr technique, which produces red silver chromate when all chloride ions have interacted.
\[2A{g^ + }\;\left( {aq} \right){\text{ }} + {\text{ }}Cr{O^{2 - }}_4\;\left( {aq} \right){\text{ }} \to {\text{ }}A{g_2}Cr{O_4}\;\left( s \right){\text{ }}({K_{sp}}\; = {\text{ }}1.1{\text{ }} \times {\text{ }}{10^{ - 12}})\]
Because silver hydroxide forms at high pH whereas chromate creates H2CrO4 at low pH, the solution must be near neutral to reduce the concentration of chromate ions and delay the development of the precipitate. Carbonates and phosphates precipitate with silver and must be avoided in order to avoid erroneous findings.
By burning a sample with calcium and subsequently ferric acetate, the Mohr technique may be used to estimate the total chlorine concentration of a sample. Free chlorine is "fixed" by calcium acetate, which precipitates carbonates and neutralises the resulting solution. Phosphates are removed by ferric acetate. The residue is dissolved and titrated to remove any chlorides.
Note:
Typically, dichlorofluorescein is employed as an indicator in the Fajans technique; the end-point is identified by the green suspension becoming pink. Chloride ions are still in excess prior to the titration's completion. They adsorb on the AgCl surface, giving the particles a negative charge. Excess silver(I) ions attach on the AgCl surface after the equivalence point, imparting a positive charge. Anionic dyes like dichlorofluorescein are attracted to the particles and change colour as they adsorb, indicating the end-point. Eosin gives a sharper end-point than dichlorofluorescein when titrating against bromide, iodide, and thiocyanate anions.
Recently Updated Pages
If x a + bt + ct2 where x is in meters and t is in class 11 physics CBSE

A car covers the first half distance between two places class 11 physics CBSE

The resultant of two vectors overrightarrow P and overrightarrow class 11 physics CBSE

Find the value of cos 135 class 11 maths CBSE

A mass M is held in place by an applied force F and class 11 physics CBSE

A solution of glucose in water is labelled as 10 dfracwv class 11 chemistry CBSE

Trending doubts
Find the value of the expression given below sin 30circ class 11 maths CBSE

One Metric ton is equal to kg A 10000 B 1000 C 100 class 11 physics CBSE

Draw a diagram of nephron and explain its structur class 11 biology CBSE

10 examples of friction in our daily life

Proton was discovered by A Thomson B Rutherford C Chadwick class 11 chemistry CBSE

Bond order ofO2 O2+ O2 and O22 is in order A O2 langle class 11 chemistry CBSE

